一、课题介绍:
1、工程概况:
金銮御林河畔1~3#楼由安徽金銮置业有限公司投资兴建,上海申联与宣城市建筑设计有限公司共同设计,安徽方信工程项目管理有限公司监理。工程建设地点位于宣城市经济技术开发区鸿越大道与莲塘路交口,属于剪力墙结构。其中1#楼地下建筑面积为580.8㎡,地上建筑面积为14294.7㎡,2#楼地下建筑面积为397.7㎡,地上建筑面积为9445.2㎡,3#楼地下建筑面积为575.7㎡,地上建筑面积为13794.2㎡,框剪结构。1-2#楼为26层,建筑高度为75.7m,3#楼为25层,建筑高度为72.80m,1#、3#楼外墙保温设计为无机保温系统,外墙保温厚度为30mm, 2#楼为挤塑聚笨板薄抹灰外墙外保温系统。厚度为30mm。
2、课题背景:
建筑节能是大家关注的热点问题,为促进节能工作的开展,我们选择了外墙外保温开展质量活动。为充分了解EPS聚苯板外保温质量现状,我们收集了大量的相关资料,列出比较突出的缺陷,以便对症下药采取相对应性措施加以解决。
图1:包装袋上未注明生产日期及批号 图2: 板材燃烧性能不达标
图3:聚苯板粘贴面积不足 图4: 接缝离开角部距离达不到20cm
图5:抹面层开裂 图6:墙面未加铺一层波纤网
图7:门窗洞口,雨篷等终端部位网格布未进行翻包 图8:网格布与聚苯板粘贴不牢固
二、小组简介:
1、小组概况:
QC小组概况表 表1
小组名称 福建华航建设集团有限公司朱铭华QC小组
成立时间 2014年9月1日 小组类型 现场型
注册日期 2014年9月1日 注册编号 FJHH-2014-10-08#
活动课题 聚苯板(EPS)薄抹灰外墙外保温系统施工质量控制
活动日期 2014年9月~2014年12月
人均接受TQC教育 60小时 合理化建议 3条