104规约模拟器 We can add up to 50 server node in the simulator. Every server node will work independently. Simulator window shows the status & connection IP Address, port number, redundancy enabled or not,If Redundancy enabled it shows, the redundant source ip address, port . The user can update the monitoring Point information, and quality bits. Send all type of commands, parameter activation, file transfer. Tested with all leading commercial test tools.
2019-12-21 20:29:16 4.91MB 104 模拟器 60870 IEC104
1
IEC 60870 part 5 [1] is one of the IEC 60870 set of standards which define systems used for telecontrol (supervisory control and data acquisition) in electrical engineering and power system automation applications. Part 5 provides a communication profile for sending basic telecontrol messages between two systems, which uses permanent directly connected data circuits between the systems. The IEC Technical Committee 57 (Working Group 03) have developed a protocol standard for telecontrol, teleprotection, and associated telecommunications for electric power systems. The result of this work is IEC 60870-5. Five documents specify the base IEC 60870-5: IEC 60870-5-1 Transmission Frame Formats IEC 60870-5-2 Data Link Transmission Services IEC 60870-5-3 General Structure of Application Data IEC 60870-5-4 Definition and Coding of Information Elements IEC 60870-5-5 Basic Application Functions IEC 60870-5-6 Guidelines for conformance testing for the IEC 60870-5 companion standards IEC TS 60870-5-7 Security extensions to IEC 60870-5-101 and IEC 60870-5-104 protocols (applying IEC 62351) The IEC Technical Committee 57 has also generated companion standards: IEC 60870-5-101 Transmission Protocols - companion standards especially for basic telecontrol tasks IEC 60870-5-102 Transmission Protocols - Companion standard for the transmission of integrated totals in electric power systems (this standard is not widely used) IEC 60870-5-103 Transmission Protocols - Companion standard for the informative interface of protection equipment IEC 60870-5-104 Transmission Protocols - Network access for IEC 60870-5-101 using standard transport profiles IEC TS 60870-5-601 Transmission protocols - Conformance test cases for the IEC 60870-5-101 companion standard IEC TS 60870-5-604 Conformance test cases for the IEC 60870-5-104 companion standard IEC 60870-5-101/102/103/104 are companion standards generated for basic telecontrol tasks, transmission of integrated totals, data exchange from protecti
2019-12-21 20:25:17 11.42MB IEC101 IEC103 IEC104 IEC60870-5
1
根据IEC104 2002规约开发,适用于读写西门子IEC104协议的电表和网关
2019-12-21 20:23:31 10.17MB IEC104
1
IEC104通信规约报文解析及IEC104通信规约解析软件,将104协议格式数据帧粘贴至解析软件,即可显示解析到的内容
2019-12-21 20:13:50 102KB IEC104 104规约
1
源代码是下载老外的,经过修改,在vs2010+qt5下编译运行。
2019-12-21 20:12:26 102KB QT5 iec104
1
本文档描述了如何使用组态王做IEC104电力规约的组态,以南自远动机做示例。
2019-12-21 20:02:53 824KB 组态王
1
IEC104系列模拟软件-包含modbus和iec系列,操作简单,易用,做模拟测试环境比较好用,可以模拟客户端和服务端,进行功能码级别的修改等。
2019-12-21 20:00:04 1.86MB iec modbus
1
IEC104规约的服务器和客户端实现,遥信遥测遥调遥控都有,学习的实际项目都能用上,VC6.0直接编译运行
2019-12-21 19:54:12 9.33MB IEC104 Server Client 遥信
1
IEC104服务端测试软件,适合于IEC104规约开发人员使用
2019-12-21 19:40:30 438KB IEC104
1
包含IEC104规约一些开发工具和相关协议的文档
2019-12-21 19:33:46 77.75MB IEC104
1