Abstract —— Grid connected wind turbines may produce flicker during continuous operation. This paper presents a simulation model of a MW-level variable speed wind turbine with a doubly fed induction generator developed in the simulation tool of PSCAD/EMTDC. Flicker emission of variable speed wind turbines with doubly fed induction generators is investigated during continuous operation, and the dependence of flicker emission on mean wind speed, wind turbulence intensity, short circuit capacity of grid and grid impedance angle are analyzed. A comparison is done with the fixed speed wind turbine, which leads to a conclusion that the factors mentioned above have different influences on flicker emission compared with that in the case of the fixed speed wind turbine. Flicker mitigation is realized by output reactive power control of the variable speed wind turbine with doubly fed induction generator. Simulation results show the wind turbine output reactive power control provides an effective means for flicker mitigation regardless of mean wind speed, turbulence intensity and short circuit capacity ratio.
2021-08-26 14:08:22 598KB 双馈风机 闪变
1
ABSTRACT —— Unbalanced grid voltage sags are the severe challenge for wind power generation system which connected to the grid successfully. The dc bus voltage and output power will fluctuate under unbalanced grid voltage. Moreover, the voltage sags will lead to the increase of peak current, which will bring potential safety hazards to the operation of wind power system. This paper proposes a simple current limiting control scheme without auxiliary equipment, which based on the detailed analysis of the excessive peak current. In this scheme, the machine side converter (MSC) controller adjusts the electromagnetic power according to the power transmitted to the grid by the grid side converter (GSC). Meanwhile, it converts the unbalanced power on the dc-link into the rotor kinetic energy, avoiding the dc-link overvoltage. The GSC controller can not only ensure that the three-phase inverter currents are in the maximum safe range that the converters can bear, but also provide reactive power support for the grid. Furthermore, the fluctuations on dc bus voltage and output power can be eliminated effectively by using the GSC controller. The feasibility of the proposed scheme and the superiority over the traditional control schemes have been verified by simulations under different types of unbalanced voltage.
1
行业分类-电子政务-MW级风力发电机组齿轮箱冷却润滑装置.zip
2021-08-25 22:02:17 188KB 行业分类-电子政务-MW级风力发
1
行业分类-电子政务-50KW风力发电机组的叶片.zip
2021-08-25 13:03:16 143KB 行业分类-电子政务-50KW风力
行业分类-电子政务-300MW发电机组高背压循环水系统.zip
2021-08-25 13:02:44 195KB 行业分类-电子政务-300MW发
行业分类-电子政务-300MW发电机组热网加热器.zip
2021-08-25 13:02:44 159KB 行业分类-电子政务-300MW发
行业分类-电子政务-660MW-1000MW发电机组连接管道用新式T型三通.zip
2021-08-25 13:02:24 183KB 行业分类-电子政务-660MW-
行业分类-电子政务-750kW集装箱式并机天然气发电机组.zip
2021-08-25 13:02:20 140KB 行业分类-电子政务-750kW集
行业分类-电子政务-一种新能源风能发电机组上塔架用塔筒.zip
1
行业分类-电子政务-一种新能源风能发电机组塔筒用米字撑.zip
1